This test facility consists of a non-magnetic stainless steel chamber approximately 1.5 m in diameter and 3.3 m in
length. The chamber is pumped by a pair of two-stage cryogenic pumping systems (CVI-TM1200). The cryopumps are
backed by a mechanical pump. In order to enhance the efficient use of this chamber, a 1.5m gate valve
has been installed to isolate the test section from the cryopumps; in this way, the cryopumps can remain operational
with the gate valve closed while adjustments are made in the test-section. Once any changes have been made and the
chamber door closed, a turbo pump is used to reduce the test-section pressure. The gate valve is then opened to
expose the cryopumps and reduce the test section to operational pressures. The pressure during typical thrust measurements
is approximately 3×10
-4 Pa, measured using an ionization gauge uncorrected for Xenon.